SI-04 · Chapter 6 · Signal Integrity & Transmission Lines

Termination choices

Compare series, parallel, Thevenin, AC (RC) and differential termination.

Level●● onsite technical
TrackSI & high-speed
Really testingPicking termination by topology and power.
Full worked answer: in the book, page 144 — what to say first, how to explain it, the numbers worth quoting and the follow-ups. About the book →

Going deeper

Extra explanation that is not in the book: worked numbers, where people go wrong, and how to say it in the room.

Worked example — power cost. A 3.3 V line held high with 50 Ω to ground: 66 mA and 0.22 W per line. Thevenin 100 Ω/100 Ω (50 Ω equivalent) draws 16.5 mA all the time and makes the driver source or sink 33 mA. A 50 Ω to VTT = 1.65 V takes ±33 mA — and the VTT supply must both source and sink (that is why DDR uses special VTT regulators).

Worked example — AC termination. For a 2 ns line, C ≈ 3·TD/Z0 = 120 pF. Smaller and the termination doesn't work; much larger and long runs of 1s or 0s shift the DC level.

Choosing, in one line each.

Where people go wrong: series-terminating a multi-drop bus — the middle receivers see the half-step shelf.